USE OF TEMPORARY ANCHORAGE DEVICES IN INTRUSION OF SUPRAERUPTED MOLARS-CASE REPORTS

  • Vesna Trpevska PHO University Dental Clinical Center St. Panteleimon, Department of Orthodontics, Skopje, Republic of North Macedonia
  • Ivan Tanatarec PHO „DR. TANATAREC“, Bitola, Republic of North Macedonia
  • Zoran Shushak PHO „Dentoria“, Ohrid, Republic of North Macedonia
  • Daniela Srbinoska PHO University Dental Clinical Center St. Panteleimon, Department of Orthodontics, Skopje, Republic of North Macedonia
  • Natasha Stavreva Department of prosthodontic, Skopje, Faculty of Dentistry, Ss. Cyril and Methodius University in Skopje, Republic of North Macedonia

Abstract

Early loss of mandibular permanent molars with supraeruption of maxillary permanent molars is a common clinical finding causing functional posterior occlusion problems. Rehabilitation of the stomatognathic system often requires preprosthodontic intervention with molar intrusion which is one of the most difficult movements in orthodontic mechanics requiring efficient anchorage to achieve success. The aim of this article was to present two case reports, with orthodontic mini-implants used for molar intrusion as preprosthetic treatment, reducing the need for prosthetic crown reduction in patients with edentulous space discrepancy. With the aid of chain elastics, the force of intrusion passing through the center of resistance of the tooth, supraerupted maxillary molars were intruded approximately 0.5mm per month. The intrusive tooth movement maintained the vitality of the intruded teeth and was not aggressive to the periodontal structures, did not cause root resorption and no change of the pulp flow was detected. In contrast to traditional orthodontics, mini-implants were demonstrated to be clinically efficient in providing sufficient anchorage against orthodontic forces. With these devices using well-controlled magnitude and direction of the force, we reestablished successfully the functional posterior occlusion. Through this case reports, we emphasize the versatility of orthodontic mini-implants as a form of temporary anchorage devices (TADs) in the biomechanics of molar intrusion attempted to create interocclusal space for adequate prosthodontic restoration with osseointegrated implants and prosthesis.


Keywords: Temporary anchorage devices (TADs), Mini-implants, Molar intrusion, Edentulous space discrepancy, Preprosthodontic therapy.

References

1. Sivakumar I, Sivakumar A. Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy. Contemp Clin Dent. 2014; 5(3):422-424. doi:10.4103/0976-237X.137982.
2. Melsen B. Limitation in adults Orthodontics. In: Melsen B, editor. Current controversies in Orthodontics. Chicago: Quintessence; 1991. p. 147-80.
3. Yao CC, Lee JJ, Chen HY, Chang ZC, Chang HF, Chen YJ. Maxillary molar intrusion with fixed appliances and mini-implant anchorage studied in three dimensions. Angle Orthod. 2005 Sept; 75(5):754-60.
4. Yao CC, Wu CB, Wu HY, Kok SH, Chang HF, Chen YJ. Intrusion of the overerupted upper left first and second molars by mini-implants with partial-fixed orthodontic appliances: a case report. Angle Orthod. 2004 Aug; 74(4):550-7.
5. Kravitz ND, Kusnoto B, Tsay TP, Hohlt WF. The use of temporary anchorage devices for molar intrusion. J Am Dent Assoc. 2007;138:56–64.
6. Janson M. A utilização rotineira dos mini-implantes na clínica ortodôntica. In: Ortodontia em adultos: e tratamento interdisciplinar. Maringá: Dental Press; 2008. p 359-405.
7. Park HS, Bae SM, Kyung HM, Sung JH. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod. 2001 July; 35(7):417-22.
8. Melsen, B. Management of severely compromised orthodontic patients. In: Nanda R, ed. Biomechanics in Clinical Orthodontics. Philadelphia, Pa: WB Saunders. 1997:294–319.
9. Carollyne Mota TIAGO1 Luis PREVIDENTE1 Paulo Roberto Aranha NOUER2 Molar intrusion with orthodontic mini-implants: case reports RGO, Rev Gaúch Odontol, Porto Alegre, v.64, n.3, p. 327-332, Jul. /set. 2016.
10. Sugii, M. M., Barreto, B., Francisco Vieira-Júnior, W., Simone, K., Bacchi, A., & Caldas, R. A. (2018). Extruded upper first molar intrusion: Comparison between unilateral and bilateral miniscrew anchorage. Dental press journal of orthodontics, 23(1), 63–70.
11. Amjad Al Taki and Mazen R Sbeih. “Bilateral Molars and Premolars Intrusion Using 2 Miniscrews and Acrylic Plate: A Case Report". Acta Scientific Dental Sciences 5.9 (2021): 116-120.
12.Sung JH, Kyung HM, Bae SM, Park HS, Kwon OW, Mc Namara Jr. A. microimplants in orthodontics. Korea: Dentos; 2006.
13. Lin JC, Liou EJ. A new bone screw for orthodontic anchorage. J Clin Orthod. 2003 Dec; 37(12):676-81.
14. Heravi F, Bayani S, Madani AS, Radvar M, Anbiaee N. Intrusion of supra-erupted molars using miniscrews: clinical success and root resorption. Am J Orthod Dentofacial Orthop. 2011 Apr; 139(4 Suppl): S170-5.
15. Pinzan-Vercelino, C., Bramante, F. S., de Araújo Gurgel, J., Vergani, E., & de Souza Gregório, R. (2017). Intrusion of maxillary molar using mini-implants: A clinical report and follow-up at 5 years. The Journal of prosthetic dentistry, 118(1), 1–4.
16. Pooktuantong O, Ogasawara T, Uezono M, Chantarawaratit P-o, Moriyama K. Optimization of Loading Condition for Maxillary Molar Intrusion with Midpalatal Miniscrews by Using Finite Element Analysis. Applied Sciences. 2021; 11(24):11749. https://doi.org/10.3390/app112411749.
17. Slabkovskaya, A., Divnich, A., Abramova, M., Slabkovsky, R., Alimova, A., & Lukina, G. (2021). CLINICAL AND RADIOGRAPHIC CHANGES FOLLOWING ORTHODONTIC INTRUSION OF OVERERUPTED MAXILLARY MOLARS WITH TWO MINI-IMPLANTS. Georgian medical news, (318), 50–56.
18. Melo AC, Jawonski ME, Largura LZ, Thomé G, Souza JR, Silva MA. Upper molar intrusion in rehabilitation patients with the aid of microscrews. Aust Orthod J. 2008 May; 24(1):50-3.
19. Umemori M, Sugawara J, Mitani H, Nagasaka H, Kawamura H. Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop. 1999 Feb; 115(2):166-74.
20. Park YC, Lee SY, Kim DH, Jee SH. Intrusion of posterior teeth using mini-screw implants. Am J Orthod Dentofacial Orthop. 2003 Jun; 123(6):690-4.
21. Park HS, Jeong SH, Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006; 130(1):18-25.
22. Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, TakanoYamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003; 124(4):373-8.
23. Buchter A, Wiechmann D, Koerdt S, Wiesmann HP, Piffko J, Meyer U. Load-related implant reaction of mini-implants used for orthodontic anchorage. Clin Oral Implants Res 2005; 16(4):473-9.
24. Roberts WE, Marshall KJ, Mozsary PG. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod 1990; 60(2):135-52.
25. Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997; 31(11):763-7.
26. Park HS, Bae SM, Kyung HM, Sung JH. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 2001; 35(7):417-22.
27. Tseng YC, Hsieh CH, Chen CH, Shen YS, Huang IY, Chen CM. The application of mini-implants for orthodontic anchorage. Int J Oral Maxillofac Surg 2006; 35(8):704-7.
28. Dalstra M, Cattaneo P, Melsen B. Load transfer of miniscrews for orthodontic anchorage. Orthod 2004; 1:53-62.
29. Liou EJ, Pai BC, Lin JC. Do miniscrews remain stationary under orthodontic forces. Am J Orthod Dentofacial Orthop 2004; 126(1):42-7.
30. Ntolou P, Tagkli A, Pepelassi E. Factors related to the clinical application of orthodontic mini-implants. J Int Oral Health 2018; 10:103-10.
31. B Wilmes et al. Maxillary molar intrusion using mini-implants in the anterior palate “Mousetrap” versus “Mini-Mousetrap”. Seminars in Orthodontics, Vol 26, No 1, 2020: pp 11-23.
32. Baumgaertel S, Smuthkochorn S, Palomo JM. Intrusion method for a single overerupted maxillary molar using only palatal mini-implants and partial fixed appliances. Am J Orthod Dentofacial Orthop. 2016 Mar;149(3):411-5. doi: 10.1016/j.ajodo.2015.10.016. PMID: 26926029.
33. Hu, Q. W., Zhao, N., Qian, W. H., & Ma, X. Q. (2018). Shanghai kou qiang yi xue = Shanghai journal of stomatology, 27(6), 629–632.
Published
2022-08-31
How to Cite
TRPEVSKA, Vesna et al. USE OF TEMPORARY ANCHORAGE DEVICES IN INTRUSION OF SUPRAERUPTED MOLARS-CASE REPORTS. Journal of Morphological Sciences, [S.l.], v. 5, n. 2, p. 191-199, aug. 2022. ISSN 2545-4706. Available at: <https://jms.mk/jms/article/view/vol5no2-26>. Date accessed: 29 mar. 2024.
Section
Articles